4.3 General Standards
4.3.1 Installation of mixers.
1 Scope of application:electrical mixers in water treatment system.
2 Check quantity:check them one by one.
3 Quality standards and inspection methods are as shown in Table 4.3.1.
Table 4.3.1 Installation of mixers
![img](https://epubservercos.yuewen.com/0C4D76/18000634808204406/epubprivate/OEBPS/Images/txt004_73.jpg?sign=1738890165-snoOkKkuQAANYDjs5WVDTGxYyMfK7DVy-0-098bf8b9d18d1ba05ec2c78bce79eb70)
4.3.2 Installation of corrosion resistant pumps.
1 Scope of application:fiber glass reinforced plastics pumps,plastic pumps,ceramic pumps,selfpriming pumps,and so on.
2 Check quantity:check them one by one.
3 Quality standards and inspection methods are as shown in Table 4.3.2.
Table 4.3.2 Installation of corrosion resistant pumps
![img](https://epubservercos.yuewen.com/0C4D76/18000634808204406/epubprivate/OEBPS/Images/txt004_74.jpg?sign=1738890165-oOa6g9Q0SBsl3BhyEp7Qn5A1FuezBjvg-0-e7d92d543f2807906fef7eadc2b60a1c)
Table 4.3.2(Continued)
![img](https://epubservercos.yuewen.com/0C4D76/18000634808204406/epubprivate/OEBPS/Images/txt004_75.jpg?sign=1738890165-t9yVweX9Y8TMXEX79x6F17TYGvH7xLRf-0-ab0e3dd2c6f2e11e536aa66934f559d3)
4.3.3 Installation of submerged vertical pumps.
1 Scope of application:installation of submerged vertical pumps for water treatment system,wastewater treatment system,etc.
2 Check quantity:check them one by one.
3 Quality standards and inspection methods are as shown in Table 4.3.3.
Table 4.3.3 Installation of submerged vertical pumps
![img](https://epubservercos.yuewen.com/0C4D76/18000634808204406/epubprivate/OEBPS/Images/txt004_76.jpg?sign=1738890165-wSCswSVvJb9ZedOqF6Qvll5pdxT5e9wZ-0-3e682dc125747fcc556cede7cd30e021)
Table 4.3.3(Continued)
![img](https://epubservercos.yuewen.com/0C4D76/18000634808204406/epubprivate/OEBPS/Images/txt004_77.jpg?sign=1738890165-ngPStzheHEMy7BfAbmi5jBRfjxrl9GGr-0-d0c56aec25231cd90730cf6ec6a23666)
4.3.4 Installation of plunger metering pumps.
1 Scope of application:water treatment system.
2 Check quantity:check them one by one.
3 Quality standards and inspection methods are as shown in Table 4.3.4.
Table 4.3.4 Installation of plunger metering pumps
![img](https://epubservercos.yuewen.com/0C4D76/18000634808204406/epubprivate/OEBPS/Images/txt004_78.jpg?sign=1738890165-EqMry9Bt91vrL3Io2nsWF8lCcSRRuEu1-0-c7fdf2e80afb9e5256ce21b773c21f6f)
4.3.5 Installation of diaphragm metering pumps.
1 Scope of application:water treatment system.
2 Check quantity:check them one by one.
3 Quality standards and inspection methods are as shown in Table 4.3.5.
Table 4.3.5 Installation of diaphragm metering pumps
![img](https://epubservercos.yuewen.com/0C4D76/18000634808204406/epubprivate/OEBPS/Images/txt004_79.jpg?sign=1738890165-VH2wJ5bsnAgUtHz6V9qP5EsgszceQfWQ-0-9d26c4221cf01087e8b9a6ce12b3a45a)
4.3.6 Installation of ordinary fans.
1 Scope of application:CO2 removal devices.
2 Check quantity:check them one by one.
3 Quality standards and inspection methods are as shown in Table 4.3.6.
Table 4.3.6 Installation of ordinary fans
![img](https://epubservercos.yuewen.com/0C4D76/18000634808204406/epubprivate/OEBPS/Images/txt004_80.jpg?sign=1738890165-XUF4CW5entpfsXAnSrWDDE2JcRX7pRMp-0-4d604601eae23d5551b46191b32f3e1f)
4.3.7 Installation of roots fans.
1 Scope of application:roots fans of various models.
2 Check quantity:check them one by one.
3 Quality standards and inspection methods are as shown in Table 4.3.7.
Table 4.3.7 Installation of roots fans
![img](https://epubservercos.yuewen.com/0C4D76/18000634808204406/epubprivate/OEBPS/Images/txt004_81.jpg?sign=1738890165-xNtNCb1MatvhzB0cEUjvnSMHCXjIqWZ3-0-0f1a4418f347fd593c8492ff61ac3e99)
Table 4.3.7(Continued)
![img](https://epubservercos.yuewen.com/0C4D76/18000634808204406/epubprivate/OEBPS/Images/txt004_82.jpg?sign=1738890165-UUQb7pBtMabAkJy1rdbkbDeLMRa9LQhO-0-b50f2f8dc1a4fa1a363bf78b79379647)
4.3.8 Installation of oil free lubrication air compressors.
1 Scope of application:oil free lubrication air compressors.
2 Check quantity:check them one by one.
3 Quality standards and inspection methods are as shown in Table 4.3.8.
Table 4.3.8 Installation of oil free lubrication air compressors
![img](https://epubservercos.yuewen.com/0C4D76/18000634808204406/epubprivate/OEBPS/Images/txt004_83.jpg?sign=1738890165-4KbUNjNi15Zlcf3UBHZI8KxSD4NC2RyE-0-f48e3a1dbaa8169ff6aa90b9779cdcbb)
Table 4.3.8(Continued)
![img](https://epubservercos.yuewen.com/0C4D76/18000634808204406/epubprivate/OEBPS/Images/txt004_84.jpg?sign=1738890165-t8dvflp7Z14EVSFgN4dxInsYtfodMxCg-0-f8dbe17c757ee3044a49f01b2a26e99d)
Table 4.3.8(Continued)
![img](https://epubservercos.yuewen.com/0C4D76/18000634808204406/epubprivate/OEBPS/Images/txt004_85.jpg?sign=1738890165-UKPxHsNT2lUJqUsn0PGfnzts2gX52QyW-0-0c15f1fed5c6c510c49fe8c333aaedd8)
Table 4.3.8(Continued)
![img](https://epubservercos.yuewen.com/0C4D76/18000634808204406/epubprivate/OEBPS/Images/txt004_86.jpg?sign=1738890165-zfzSJ3w3XGtwK14hST6y9l6oxdFffIvd-0-ddbc1a0fbc14efa0e8b857e8760411ad)
4.3.9 Installation of air purification devices.
1 Scope of application:air purification device.
2 Check quantity:check them one by one.
3 Quality standards and inspection methods are as shown in Table 4.3.9.
Table 4.3.9 Installation of air purification devices
![img](https://epubservercos.yuewen.com/0C4D76/18000634808204406/epubprivate/OEBPS/Images/txt004_87.jpg?sign=1738890165-NaQBjSM0N4X9WyQzGH8VCHZELcpl6klh-0-f2730c41382a6aac139e5a114a1b341b)
4.3.10 Installation of storage tanks.
1 Scope of application:compressed air storage tanks,hot water tanks.
2 Check quantity:check them one by one.
3 Quality standards and inspection methods are as shown in Table 4.3.10.
Table 4.3.10 Installation of storage tanks
![img](https://epubservercos.yuewen.com/0C4D76/18000634808204406/epubprivate/OEBPS/Images/txt004_88.jpg?sign=1738890165-yDwhEcN2AweWDhz0NPUpLnmDHROV5kaa-0-c709b6d0f37cb9014552192d3a86f907)
4.3.11 Installation of chemical dosing devices.
1 Scope of application:chemical dosing devices for coagulant,coagulant aids,flocculant,scale inhibitor,defoaming agent,germicide,algicide,acid,alkali,sodium sulfite,ammonia,hydrazine,phosphate,etc.
2 Check quantity:check them one by one.
3 Quality standards and inspection methods are as shown in Table 4.3.11.
Table 4.3.11 Chemical dosing devices
![img](https://epubservercos.yuewen.com/0C4D76/18000634808204406/epubprivate/OEBPS/Images/txt004_89.jpg?sign=1738890165-NpVZmOjljJiL3HEqSylHqUHLzGOcVMLv-0-8fef7bdea1a8138f3ad7a408f61473bc)
Table 4.3.11(Continued)
![img](https://epubservercos.yuewen.com/0C4D76/18000634808204406/epubprivate/OEBPS/Images/txt004_90.jpg?sign=1738890165-VVJMVFxERDrKp9l8lOBFmZjsFxUrsGNk-0-3c9cac18f89eef44af6e21a3808851de)
4.3.12 Installation of lime pipes.
1 Scope of application:lime slurry pipes,magnesite slurry pipes.
2 Check quantity:check section by section according to the system.
3 Quality standards and inspection methods are as shown in Table 4.3.12.
Table 4.3.12 Installation of lime pipes
![img](https://epubservercos.yuewen.com/0C4D76/18000634808204406/epubprivate/OEBPS/Images/txt004_91.jpg?sign=1738890165-4Ho785vDWatRSEFKXClXEZD2rGdq0rzy-0-a0c5554d41bb96cb06496a5247bc16dd)
4.3.13 Installation of rubber lined pipes.
1 Scope of application:demineralized water,circulating water treatment,condensate treatment and chemical dosing systems.
2 Check quantity:check them section by section or randomly according to the system,pipes and pipe fittings of the acid system shall be checked one by one.
3 Quality standards and inspection methods are as shown in Table 4.3.13.
Table 4.3.13 Installation of rubber lined pipes
![img](https://epubservercos.yuewen.com/0C4D76/18000634808204406/epubprivate/OEBPS/Images/txt004_92.jpg?sign=1738890165-7rIAtZA9zUP0XERyLRDGByESp6vib5Zy-0-dadb89794ff7b6d663abb6fc53804ba2)
Table 4.3.13(Continued)
![img](https://epubservercos.yuewen.com/0C4D76/18000634808204406/epubprivate/OEBPS/Images/txt004_93.jpg?sign=1738890165-HkBiMVLoZ80Z8VoTlgaaQVOMjuc8jTgD-0-e152a8d4464a86922974bda9977ffdc5)
4.3.14 Installation of plastic lined pipes.
1 Scope of application:demineralized water,circulating water treatment,condensate treatment and chemical dosing systems.
2 Check quantity:check them section by section or randomly according to the system.
3 Quality standards and inspection methods are as shown in Table 4.3.14.
Table 4.3.14 Installation of plastic lined pipes
![img](https://epubservercos.yuewen.com/0C4D76/18000634808204406/epubprivate/OEBPS/Images/txt004_94.jpg?sign=1738890165-6Pd2EvbPPi5E48SY4VSoqL0LXpDtIcRA-0-94870c0e901a2e9a227fff11b419402a)
Table 4.3.14(Continued)
![img](https://epubservercos.yuewen.com/0C4D76/18000634808204406/epubprivate/OEBPS/Images/txt004_95.jpg?sign=1738890165-oXoWldW6TNGsp2Zvk1hWfTJeZ8vz63V5-0-8e1a93670c7e6c0446aaa8a22d4b9cf5)
4.3.15 Installation of fiber glass reinforced plastics pipes.
1 Scope of application:water treatment system.
2 Check quantity:check them section by section according to the system.
3 Quality standards and inspection methods are as shown in Table 4.3.15.
Table 4.3.15 Installation of fiber glass reinforced plastics pipes
![img](https://epubservercos.yuewen.com/0C4D76/18000634808204406/epubprivate/OEBPS/Images/txt004_96.jpg?sign=1738890165-n02wBCi24qQ0fz7jpa2qf3y180ClPsCD-0-b3b8cbaaed5af632203b0d7fb54aca14)
4.3.16 Installation of plastic pipes.
1 Scope of application:water treatment system.
2 Inspection quantity:check them section by section according to the system.
3 Quality standards and inspection methods are as shown in Table 4.3.16.
Table 4.3.16 Installation of plastic pipes
![img](https://epubservercos.yuewen.com/0C4D76/18000634808204406/epubprivate/OEBPS/Images/txt004_97.jpg?sign=1738890165-kTWcd0oreMSq6qn7bbqJLZvyjoKNzxEB-0-3f57eb3febdb0eb4e2ccad784dae4532)
4.3.17 Installation of composite pipes.
1 Scope of application:the composite pipes like steel framed pipes,hot melted pipes,mesh steel reinforced pipes.
2 Inspection quantity:check them section by section or randomly according to the system.
3 Quality standards and inspection methods are as shown in Table 4.3.17.
Table 4.3.17 Installation of composite pipes
![img](https://epubservercos.yuewen.com/0C4D76/18000634808204406/epubprivate/OEBPS/Images/txt004_98.jpg?sign=1738890165-BUtYXTShCbkAwsM4I0YId4Xs8mdI595G-0-f5de95016e6541e2a4b5b6caf30bd74d)
4.3.18 Installation of stainless steel pipes.
1 Scope of application:water treatment and hydrogen station system.
2 Inspection quantity:check them section by section or randomly according to the system.
3 Quality standards and inspection methods are as shown in Table 4.3.18.
Table 4.3.18 Installation of stainless steel pipes
![img](https://epubservercos.yuewen.com/0C4D76/18000634808204406/epubprivate/OEBPS/Images/txt004_99.jpg?sign=1738890165-8lUdlw6aaF6ECqHZNwAoIjvEM9CMQS1d-0-7278604e9f4df4ea893a812e03d4dc3f)
4.3.19 Installation of special valves.
1 Scope of application:various lined valves and non-metal valves.
2 Inspection quantity:check them one by one.
3 Quality standards and inspection methods are as shown in Table 4.3.19.
Table 4.3.19 Installation of special valves
![img](https://epubservercos.yuewen.com/0C4D76/18000634808204406/epubprivate/OEBPS/Images/txt004_100.jpg?sign=1738890165-cibUcOLhnAatSrIBZYjwOfzFWb9IsspU-0-7c4e400e88d19dddde394e30d592ce67)
4.3.20 Installation of special pipe supports and hangers.
1 Scope of application:stainless steel pipes,non-metal pipes,composite pipes.
2 Inspection quantity:check them one by one.
3 Quality standards and inspection methods are as shown in Table 4.3.20.
Table 4.3.20 Installation of special pipe supports and hangers
![img](https://epubservercos.yuewen.com/0C4D76/18000634808204406/epubprivate/OEBPS/Images/txt004_101.jpg?sign=1738890165-IM9Sf8MNIub1MVl7mA2lVs9fr4ZmsnSU-0-354a53864ca6df3de358dcec086a31d3)
Table 4.3.20(Continued)
![img](https://epubservercos.yuewen.com/0C4D76/18000634808204406/epubprivate/OEBPS/Images/txt004_102.jpg?sign=1738890165-47D1uupMLTSXueoxnZh2wLQ7q9dXFuYF-0-9cf249c4ccdfe0d66eb18cd3664e2f38)
4.3.21 Valve adjustment.
1 Scope of application:water treatment system,electric,pneumatic valves and pressure reducing valves.
2 Inspection quantity:check them one by one.
3 Quality standards and inspection methods are as shown in Table 4.3.21.
Table 4.3.21 Valve adjustment
![img](https://epubservercos.yuewen.com/0C4D76/18000634808204406/epubprivate/OEBPS/Images/txt004_103.jpg?sign=1738890165-PbGWAIGWcM6xxBb6AlWK8lR9Lxoe0oPS-0-a1e6cc32c82a4418f0f5a91a1200eba3)
4.3.22 Hydraulic,water filling test.
1 Scope of application:water treatment system.
2 Inspection quantity:check them item by item.
3 Quality standards and inspection methods are as shown in Table 4.3.22.
Table 4.3.22 Hydraulic,water filling test
![img](https://epubservercos.yuewen.com/0C4D76/18000634808204406/epubprivate/OEBPS/Images/txt004_104.jpg?sign=1738890165-K4SbQIzUuiV99e5HVc9d3OVbbayf2vhx-0-91ae0c7d178f74e76a53724b7c36da4a)
4.3.23 Air pressure test.
1 Scope of application:water treatment and hydrogen generation equipment and system with design pressure not higher than 0.6MPa.
2 Inspection quantity:check them item by item.
3 Quality standards and inspection methods are as shown in Table 4.3.23.
Table 4.3.23 Air pressure test
![img](https://epubservercos.yuewen.com/0C4D76/18000634808204406/epubprivate/OEBPS/Images/txt004_105.jpg?sign=1738890165-nyD3AGE1lGyBNzCRHxg1Emvxd9d9NBrf-0-c9d8ffe1abe7214c1c53eebdc79a67d7)
4.3.24 Trial run of water pumps.
1 Scope of application:corrosion resistant pumps,submerged vertical pumps of water treatment system.
2 Inspection quantity:check them one by one.
3 Quality standards and inspection methods are as shown in Table 4.3.24.
Table 4.3.24 Trial run of water pumps
![img](https://epubservercos.yuewen.com/0C4D76/18000634808204406/epubprivate/OEBPS/Images/txt004_106.jpg?sign=1738890165-5rEUecCrm3PXrrLRXGiWiYUtyRq3wdco-0-aa79674c5ef6fa0951eebc24735e1765)
4.3.25 Trial run of reciprocating pumps.
1 Scope of application:plunger pumps,diaphragm pumps of water treatment system.
2 Inspection quantity:check them one by one.
3 Quality standards and inspection methods are as shown in Table 4.3.25.
Table 4.3.25 Trial run of plunger pumps,diaphragm pumps
![img](https://epubservercos.yuewen.com/0C4D76/18000634808204406/epubprivate/OEBPS/Images/txt004_107.jpg?sign=1738890165-9ThHsOceE2xF5UZENj98ZPMnJuSB1O41-0-3ee542b6da96e69a0ec162bb2e696e0b)
4.3.26 Trial run of fans.
1 Scope of application:carbon removal fans,roots fans and air compressors.
2 Inspection quantity:check them one by one.
3 Quality standards and inspection methods are as shown in Table 4.3.26.
Table 4.3.26 Trial run of fans
![img](https://epubservercos.yuewen.com/0C4D76/18000634808204406/epubprivate/OEBPS/Images/txt004_108.jpg?sign=1738890165-7P6fD9P8cGGJh9D2l1N50QP9gVl0Y9L0-0-4ebdfabee4726ed6b66dadeb14d28af0)
Table 4.3.26(Continued)
![img](https://epubservercos.yuewen.com/0C4D76/18000634808204406/epubprivate/OEBPS/Images/txt004_109.jpg?sign=1738890165-XryA7KIl0hPDBppUD5XkbRdID3CzMnjT-0-edbfd2d1c14ee88a16ddae8222f7bb73)
4.3.27 Trial run of self-cleaning filter.
1 Scope of application:various types of self-cleaning filters of water treatment system.
2 Inspection quantity:check them one by one.
3 Quality standards and inspection methods are as shown in Table 4.3.27.
Table 4.3.27 Trial run of self-cleaning filters
![img](https://epubservercos.yuewen.com/0C4D76/18000634808204406/epubprivate/OEBPS/Images/txt004_110.jpg?sign=1738890165-pwCwnA85GinRWUwZoGtEjiYVv2WzLLBm-0-c84523dfd50c2b74d544681fe211407a)
Table 4.3.27(Continued)
![img](https://epubservercos.yuewen.com/0C4D76/18000634808204406/epubprivate/OEBPS/Images/txt004_111.jpg?sign=1738890165-9HjKy4yqxq9lskINDo2mPWEBs0rVZYGw-0-0620e1221e9bdd65c1e5e41850132b42)
4.3.28 Trial run of mixers.
1 Scope of application:various types of mechanical mixers of water treatment system.
2 Inspection quantity:check them one by one.
3 Quality standards and inspection methods are as shown in Table 4.3.28.
Table 4.3.28 Trial run of mixers
![img](https://epubservercos.yuewen.com/0C4D76/18000634808204406/epubprivate/OEBPS/Images/txt004_112.jpg?sign=1738890165-z2Wvn0HyzyxFKiTP4RFQriPQRqXRA5P3-0-77855425c2ca51139ff11433d8fa08cf)
4.3.29 Trial run of chemical dosing devices.
1 Scope of application:chemical dosing devices for coagulant,coagulant aids,flocculant,scale inhibitor,deforming agent,germicide,algicide,acid,alkali,sodium sulfite,ammonia,hydrazine,phosphate,etc.
2 Inspection quantity:check them one by one.
3 Quality standards and inspection methods are as shown in Table 4.3.29.
Table 4.3.29 Trial run of chemical dosing devices
![img](https://epubservercos.yuewen.com/0C4D76/18000634808204406/epubprivate/OEBPS/Images/txt004_113.jpg?sign=1738890165-UL3SCo3dQhegcvsjYbVvlPRayR5vuYQQ-0-13c8749d7436cf5b80665da23532e54c)
4.3.30 Water flushing.
1 Scope of application:water treatment system.
2 Inspection quantity:check them one by one.
3 Quality standards and inspection methods are as shown in Table 4.3.30.
Table 4.3.30 Water flushing
![img](https://epubservercos.yuewen.com/0C4D76/18000634808204406/epubprivate/OEBPS/Images/txt004_114.jpg?sign=1738890165-dZDNs45f1udrZPbC9fmMRo2MxD7YNjwQ-0-9172130fdd52383538ee80d29863f8c4)
4.3.31 Air purging.
1 Scope of application:water treatment system and hydrogen station system.
2 Inspection quantity:check them one by one.
3 Quality standards and inspection methods are as shown in Table 4.3.31.
Table 4.3.31 Air purging
![img](https://epubservercos.yuewen.com/0C4D76/18000634808204406/epubprivate/OEBPS/Images/txt004_115.jpg?sign=1738890165-VSmBBeh0oLdpbAkzSvcLh1zbm2ZtpaWr-0-d7f23fd23af9d29b163e613f1ea31c2b)
4.3.32 Steam purging.
1 Scope of application:sea water desalination system.
2 Inspection quantity:check them one by one.
3 Quality standards and inspection methods are as shown in Table 4.3.32.
Table 4.3.32 Steam purging
![img](https://epubservercos.yuewen.com/0C4D76/18000634808204406/epubprivate/OEBPS/Images/txt004_116.jpg?sign=1738890165-5yV6rIpAeu06a4OOVN4XLAzav8yXjiwZ-0-c7f2637121a83a94f862d2d8c4e82487)